Kingsine Electric Automation Co., Ltd.

Kingsine Electric Automation Co., Ltd. Specialize in Electric Power Testing

Manufacturer from China
Verified Supplier
17 Years
Home / Products / CT Analyzer /

CT / PT Analyzer

Contact Now
Kingsine Electric Automation Co., Ltd.
Visit Website
City:shenzhen
Province/State:guangdong
Contact Person:MissAmy
Contact Now

CT / PT Analyzer

Ask Latest Price
Video Channel
Place of Origin :China
Brand Name :Kingsine
Certification :ISO9001,CE
Model Number :KT200
MOQ :1 set
Delivery Time :15 working days
Payment Terms :T/T in advance ,L/C
Supply Ability :50 sets/ month
Contact Now

Add to Cart

Find Similar Videos
View Product Description

CT / PT Analyzer

TFT LCD display screen
IEC 60044-1 / IEC60044-6 standard
Power Supply Input:AC:85-260 V, 47-63 Hz, 10 A(max.)

Innovative Design, easy Maintenance!


With innovative modularize design, Plug-in frame, self-calibration function which make maintenance more easy!


1, Consisting of Function modularization design and plug-in frame, each module contains self-calibration function, plug and play when change module, easy to maintain for customer.

2, Adopt TFT LCD display screen with clear and beautiful software interface design, user can operate easily

3, AC/DC current input for wide range only, satisfy all power supply standard requested.

4, Easy to operate, measure quickly, all test can be done automatically based on the same connection line type except overload impedance measurement.

5, Adopt low voltage & variable frequency measurement method, it can test inflexion voltage up to 30kV transformer as output max voltage only is 120V and max peak value current is 15A, high security.

6, Portable design with light weight of 10kg, suitable for field test of electric power system, manufacturing factory of current transformer or laboratory to use.

7, High measurement accuracy, resistance accuracy is 0.1%+1mΩ, phase accuracy±0.05 degree, variable accuracy is ±0.1% (1-5000 ), variable accuracy is ±0.2%(5000-10000)

8, It can test current transformer according to IEC 60044-1 or IEC60044-6 standard etc.

9, Complete measurement function, it can test all type current transformer for secondary overload, secondary loop resistance, excitation characteristic, transient characteristic, ratio difference, angle difference and polarity. It can also test exact limit coefficient(ALF), device security coefficient(FS), secondary time constant(Ts), remanence coefficient(Kr), transient area coefficient(Ktd), inflexion voltage, current, level, saturation inductance, un-saturation inductance, 5% 10% error curve, of current transformer, hysteresis loop for current transformer, and evaluate test result according to defined standard.

10. PT Test
As for those inductive PT based on the definition of GB1207-2006(IEC60044-2), KT200 CT/PT Analyzer can also test them. KT200 CT/PT Analyzer can do variable ratio, polarity and secondary winding excitation test of inductive PT.

CT / PT Analyzer

Technical Parameters List

Power Supply Input

AC:85-260 V, 47-63 Hz, 10 A(max.)

Variable Ratio Measurement

Range:1-5000, accuracy: ±0.1%

Range:5000-10000, accuracy: ±0.2%

Voltage Output

0-120 V(AC)

Phase Measurement

Accuracy: ±3 min, resolution:0.01 min

Current Output

0-5 A(RMS)

Peak value: 15 A

Secondary Winding

Resistance Measurement

Range:0.1-10 0 Ω

Accuracy: 0.1%+1mΩ, resolution: 1mΩ

Power Output

0-450 VA,

Peak value: 1500 VA

AC Load Measurement

0-300 VA

Resolution: 0.01 VA

Current

Measurement

Range:0-15A(automatic range), Accuracy: ±0.1%

Working Condition

Temperature:-10°C-55°C

Humidity:£95%

Voltage

Measurement

Range:0-30 V(automatic range), accuracy: ±0.1%

Range:0-300 V(automatic

range), accuracy: ±0.1%

Dimension and Weight

360mm×325mm×140mm

10 kg

Inquiry Cart 0