PMC100 series single phase digital power meter adopts customized, modularized, high brightness LED display, very beautiful and grand; use low-power microprocessor as core, to achieve all-electric parameter measurement and energy metering. Can optional configure various binary, relay, analog output interface to achieve user’s various needs; integrates RS-485 communication ports, can easily fulfill the integration of various intelligent distribution System. The product function is practical, easy to use and maintenance. Can be used in on-site equipment monitoring and control , provide measure support for electric application experts, provide data basis for SCADA and Smart Grid, provide decision-making basis for effective intelligent energy management.
Function Features
Function Features | PMC100Z | PMC100C | PMC100P | PMC100F | PMC100U | PMC100I | PMC100N |
Instantaneous real virtual value |
|
|
|
|
|
|
|
Current | ◆ |
| ◆ |
|
| ◆ | ◆ |
Voltage | ◆ |
| ◆ |
| ◆ |
| ◆ |
Frequency | ◆ |
|
| ◆ |
|
| ◆ |
Active power | ◆ |
| ◆ |
|
|
| ◆ |
Reactive power | ◆ |
|
|
|
|
| ◆ |
Power factor | ◆ | ◆ |
|
|
|
| ◆ |
Energy |
|
|
|
|
|
|
|
Active energy | ◆ |
|
|
|
|
| ◆ |
Communication |
|
|
|
|
|
|
|
RS485 /MODBUS protocol | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ |
Display |
|
|
|
|
|
|
|
LED display | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ |
|
Other |
|
|
|
|
|
|
|
2-channel DI | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ |
|
2-channel DO | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ |
|
1 channel AO :4-20mA | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ |
|
2-channel limits alarm | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ |
Support program online upgrade | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ |
Technical Parameter
Electrical Characteristics | ||
Measurement Type | Single phase AC system | |
| Sampling rate per cycle: 64 times | |
Data refresh rate | 1S | |
Measurement Accuracy
| Current | 0.2% |
Voltage | 0.2% | |
Power | 0.5% | |
Frequency | 0.05Hz | |
Active Energy | 1.0% | |
AO | 1% | |
Input voltage characteristics | Measuring voltage | 0~600 V (Direct Access) |
Allowed overload | 1.2 times / continuous | |
Input impedance | 1.8MΩ | |
Input current characteristic | Measuring current | 5A or 1A (Via CT Connect) |
Allowed overload | 1.2 times / continuous | |
Input impedance | <0.1Ω | |
Binary INPUT | Working voltage | 12~24 VDC (external power supply) |
Input impedance | 12KΩ | |
Isolation voltage | 2KV | |
Relay output | Node Type | Mechanical shock |
Node capacity | 220 VAC/5A, 30 VDC/5A | |
4-20mA DC Output | Open circuit voltage | 5VDC |
Overload capacity | ≤200Ω | |
Isolation voltage | 2KV | |
Working power supply | AC | 85~265 VAC/45-65Hz |
DC | 100~300 VDC | |
Power dissipation | <2.5W | |
Mechanical properties | ||
Weight | 0.3kg | |
IP protection grade | panel IP52, body IP30 | |
Size | 96 X 48 X 72 mm | |
Operating temperature | -25~70℃ | |
Storage Temperature | -40~85℃ | |
Relative Humidity | 5% - 90%RH, No condensation | |
EMC | ||
Electrostatic discharge interference | IEC 61000-4-2, Level 4 | |
Group of anti-fast transient pulse | IEC 61000-4-4, Level 4 | |
Anti-impact | IEC 61000-4-5, Level 3 | |
Anti-frequency magnetic field | IEC 61000-4-8, Level 3 | |
Electrical insulation performance | ||
Insulation resistance | GB/T13729, >50MΩ | |
Frequency withstand voltage | GB/T13729, AC 2KV 50Hz /1min | |
Impulse voltage | GB/T13729, 5KV, 1.2/50us |