Kingsine Electric Automation Co., Ltd.

Kingsine Electric Automation Co., Ltd. Specialize in Electric Power Testing

Manufacturer from China
Verified Supplier
16 Years
Home / Products / Secondary Injection Test Set /

Good Stability Secondary Injection Test Set 4 Phase K3030

Good Stability Secondary Injection Test Set 4 Phase K3030

Ask Latest Price
Place of Origin :China
Brand Name :Kingsine
Model Number :K3030
Certification :ISO9001,CE
MOQ :1 set
Delivery Time :15 working days
Payment Terms :T/T in advance ,L/C
Supply Ability :50 sets/ month
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

Good Stability Secondary Injection Test Set 4 Phase K3030

1.wide pressure rang
2.high accuracy
3.Current, Volt measuring
4.easy to operation

Friendly PC software for easy operation!

K30 series relay tester is extremely design for overseas user, with Friendly PC software as your need, unique features and functions helps you all the way!

1. Unique self-protection system assure the powerful protection when instrument is operating, automatic stop the output when the network is abnormal ;
2. Unique power switch and amplifier technology, so the output precision and power efficiency and factor are increased, which conforms to international tendency of energy save and environmental protection;
3. With alarm function of housing grounding testing and external voltage input, to guaranty personal security;
4. Two in one of meter and source, with function of both internal and external testing, self-calibration, oscillograph, and the duration of each oscillograph reaches 50S (optional function);
5. Offer independent Aux. DC to tested devices, 0 ~ 300V/0.6A (Poleless and adjustable);
6. Function of transducer and energy meter testing (optional function);
7. Testing interface offer unique output monitoring function and Pre-curve-tracing function, helps more on the spot analysis;

Technical Data of K3030

Voltage generators

Setting

Range

4-phase AC (L-N)

4 x 0 ... 130 V

2-phase AC (L-L)

2 x 0 ... 260 V

Power

4-phase AC (L-N)

4 x 70VA, at 0 ... 130 V

2-phase AC (L-L)

2 x 140VA, at 0 ...260 V

Accuracy

<0.07% reading + 0.03% range guaranteed

at 0 ... 130 V

<0.02% reading + 0.01% range typical

at 0-130V

Resolution

1mV

Current generators

Setting

Range

3-phase AC (L-N)

3 x 0 ... 30 A

1-phase AC (2L-N)

1 x 0 ... 60 A

1-phase AC (3L-N)

1 x 0 ... 90 A

Power

3-phase AC (L-N)

3x 450VA , at 0 ... 30A

1-phase AC (2L-N)

1x 520VA, at 0 ... 60A

1-phase AC (3L-N)

1 x 1200 VA, at 0 ... 90A (Max.)

Accuracy

<0.07% reading + 0.06% range guaranteed at 0-30A

<0.02% reading + 0.02% range typical at 0-30A

Resolution

1mA

Generators, general

Frequency

Range

0 ... 1000 Hz

Accuracy / drift

Error < 0.001Hz at 10 ... 65Hz,

Error < 0.01Hz at 65Hz...450Hz

Error < 0.02Hz at 450Hz...1000Hz

Resolution

0.001Hz

Phase

Range

- 360° ... +360°

Accuracy / drift

Error < 0.2 °

Resolution

0.1°

Timer

Range

Infinite

Accuracy / drift

Error<0.1ms

DC generators

Voltage ranges

0 ... 300V/180W

Current ranges

0 ... 20A/300W

Accuracy

<0.07% reading + 0.03% range guaranteed at 0-300V

<0.04% reading + 0.02% range typical at 0-300V

<0.14% reading + 0.06% range guaranteed at 0-20A

<0.05% reading + 0.02% range typical at 0-20A

Resolution

1mA; 1 mV

Aux DC Supply

Range

0...300V/0.6A

Binary inputs

Number

8 pairs

Compatible Voltage

10V ... 250V DC

Binary outputs

Number

4 Pairs

Capacity

250V/3A AC/DC

Synchronization

Synchronization mode

GPS

Harmonic

Harmonic overlap times

2 ... 20 times

Power supply

Nominal input voltage

220VAC±20%

Power

1000VA

Nominal frequency

47Hz….65Hz

Environmental conditions

Operation temperature

-5°C ... 55 °C

Storage temperature

-20°C ... 75 °C

Humidity range

5% ... 90 %, non-condensing

Weight

20 KG

Dimensions

460(D)×140 (W)×360 (H) mm

PC connection

RJ45,

K30 Series Protection Relay Test Set:

Model

Channels

AC Outputs

K3063i / K3063Li

10 output channels

6*30A/3*40A/4*300V

K3030i / K3030Li

7 output channels

3*30A/4*300V

K3066

13 output channels

6*20A/3*40A/7*130V

K3063

10 output channels

6*20A/3*40A/4*130V

K3040

7 output channels

3*40A/4*130V

K3030

7 output channels

3*30A/4*130V

Major functions:

Items

IEEE(R) No.

Synchronization relay

Fault transplay

GPS Synchronization

Overcurrent relays

50/76

Inverse time overcurrent relays

51

Undercurrent relays

37

Ground fault relays

50

Directional overcurrent relays

67

Directional ground fault relays

67N

Overvoltage relays

59

Undervoltage relays

27

Directional voltage relays

91

Directional power relays

32

Power factor relays

55

Differential protection (differential circuits)

87

Distance protection equipment (phase by phase)

21

Negative sequence overcurrent relays

46N

Motor overload protection

51/86

Automatic reclosing devices

79

Tripping relays

94

Voltage regulating relays

Overimpedance relays, Z>

Underimpedance relays, Z

Time-delay relays

Good Stability Secondary Injection Test Set 4 Phase K3030

China Good Stability Secondary Injection Test Set 4 Phase K3030 for sale

Good Stability Secondary Injection Test Set 4 Phase K3030

Inquiry Cart 0